Everything about Insulator Electrical totally explained
An
Insulator is a material that resists the flow of
electric current. It is an object intended to support or separate electrical
conductors without passing current through itself. An insulation material has atoms with tightly bonded
valence electrons. The term
electrical insulation has the same meaning as the term
dielectric.
Some materials such as
silicon dioxide or
teflon are very good electrical insulators. A much larger class of materials, for example rubber-like polymers and most plastics are still "good enough" to insulate
electrical wiring and
cables even though they may have lower bulk
resistivity. These materials can serve as practical and safe insulators for low to moderate voltages (hundreds, or even thousands, of
volts).
Physics of conduction in solids
Electrical insulation is the absence of
electrical conduction. Electronic
band theory (a branch of physics) predicts that a charge will flow whenever there are states available into which the electrons in a material can be excited. This allows them to gain energy and thereby move through the conductor (usually a
metal). If no such states are available, the material is an insulator.
Most (though not all, see
Mott insulator) insulators are characterized by having a large
band gap. This occurs because the "valence" band containing the highest energy electrons is full, and a large energy gap separates this band from the next band above it. There is always some voltage (called the
breakdown voltage) that will give the electrons enough energy to be excited into this band. Once this voltage is exceeded, the material ceases being an insulator, and charge will begin to pass through it. However, it's usually accompanied by physical or chemical changes that permanently degrade the material's insulating properties.
Materials which lack electron conduction must also lack other mobile charges as well. For example, if a liquid or gas contains ions, then the ions can be made to flow as an electric current, and the material is a conductor.
Electrolytes and
plasmas contain ions and will act as conductors whether or not electron flow is involved.
Telegraph and power transmission insulators
Suspended wires for
electric power transmission are bare, except when connecting to houses, and are insulated by the surrounding air and where connected to towers, as detailed below.
Material
High-voltage insulators used for high-voltage
power transmission are made from
glass,
porcelain, or
composite polymer materials. Porcelain insulators are made from
clay,
quartz or
alumina and
feldspar, and are covered with a smooth glaze to shed dirt. The design of insulators often includes deep grooves, or sheds, that provides increased arc-lengths. Insulators made from porcelain rich in
alumina are used where high mechanical strength is a criterion. Glass insulators were (and in some places still are) used to suspend electrical power lines. Some insulator manufacturers stopped making glass insulators in the late 1960s, switching to various ceramic and, more recently, composite materials.
Recently, some electric utilities have begun converting to polymer
composite materials for some types of insulators which consist of a central rod made of
fibre reinforced plastic and an outer weathershed made of
silicone rubber or
EPDM. Composite insulators are less costly, lighter in weight, and have excellent
hydrophobic capability. This combination makes them ideal for service in polluted areas. However, these materials don't yet have the long-term proven service life of glass and porcelain.
History
The first electrical systems to make use of insulators were
telegraph lines; direct attachment of wires to wooden poles was found to give very poor results, especially during damp weather.
The first glass insulators used in large quantities had an unthreaded pinhole. These pieces of glass were positioned on a tapered wooden pin, vertically extending upwards from the pole's crossarm (commonly only two insulators to a pole and maybe one on top of the pole itself). Natural contraction and expansion of the wires tied to these "threadless insulators" resulted in insulators unseating from their pins, requiring manual reseating.
Amongst the first to produce ceramic insulators were companies in the United Kingdom, with Stiff and Doulton using
stoneware from the mid 1840s, Joseph Bourne (later renamed Denby) producing them from around 1860 and Bullers from 1868.
Utility patent number
48,906
was granted to Louis A. Cauvet on
July 25,
1865 for a process to produce insulators with a threaded pinhole. To this day, pin-type insulators still have threaded pinholes.
The invention of suspension-type insulators made high-voltage power transmission possible. Pin-type insulators were unsatisfactory over about 60,000 volts.
A large variety of telephone, telegraph and power insulators have been made; some people collect them.
Insulation of antennas
In most cases a
broadcasting radio antenna requires an insulating mounting, therefore insulators of
steatite are used. They have to withstand not only the voltage of the mast radiator to ground, which can reach values up to 400 kV at some antennas, but also the weight of the mast construction and dynamic forces. Arcing horns and lightning arresters are necessary because lightning strikes in the mast are common.
At guyed mast radiators, it's often necessary to use insulators in the guy (if they're not grounded via a coil at the anchor bases), in order to prevent undesired electrical resonances of the guys. These insulators also have to be equipped with overvoltage protection equipment. For the dimensions of the guy insulation, static charges on guys have to be considered, at high masts these can be much higher than the voltage caused by the transmitter requiring guys divided by insulators in multiple sections on the highest masts. In this case, guys which are grounded at the anchor basements via a coil - or if possible, directly - are the better choice.
Insulation in electrical apparatus
The most important insulation material is air. A wide variety of solid, liquid, and gaseous insulators are also used in electrical apparatus. In smaller
transformers,
generators, and
electric motors, insulation on the wire coils consists of up to four thin layers of polymer varnish film. Film insulated
magnet wire permits a manufacturer to obtain the maximum number of turns within the available space. Windings that use thicker conductors are often wrapped with supplemental fiberglass insulating tape. Windings may also be impregnated with insulating varnishes to prevent
electrical corona and reduce magnetically induced wire vibration. Large power transformer windings are still mostly insulated with paper, wood, varnish, and
mineral oil; although these materials have been used for more than 100 years, they still provide a good balance of economy and adequate performance.
Busbars and
circuit breakers in
switchgear may be insulated with glass-reinforced plastic insulation, treated to have low flame spread and to prevent tracking of current across the material.
In older apparatus made up to the early 1970s, boards made of compressed
asbestos may be found; while this is an adequate insulator at power frequencies, handling or repairs to asbestos material will release dangerous fibers into the air and must be carried out with caution. Live-front switchboards up to the early part of the 20th century were made of slate or marble.
Some high voltage equipment is designed to operate within a high pressure insulating gas such as
sulfur hexafluoride.
Insulation materials that perform well at power and low frequencies may be unsatisfactory at
radio frequency, due to heating from excessive dielectric dissipation.
Electrical wires may be insulated with
polyethylene, crosslinked polyethylene (either through
electron beam processing or chemical crosslinking),
PVC, rubber-like polymers, oil impregnated paper,
Teflon, silicone, or modified ethylene tetrafluoroethylene (
ETFE). Larger
power cables may use
compressed inorganic powder, depending on the application.
Flexible insulating materials such as
PVC (polyvinyl chloride) are used to insulate the circuit and prevent human contact with a 'live' wire -- one having voltage of 600 volts or less. Alternative materials are likely to become increasingly used due to EU safety and environmental legislation making PVC less economic.
Class 1 and Class 2 insulation
All portable or hand-held electrical devices are insulated to protect their user from harmful shock.
Class 1 insulation requires that the metal body of the apparatus/equipment is solidly connected via a "grounding" wire which is earthed at the main Service Panel; but only
basic insulation of the conductors is needed. This equipment is easily identified by a third pin for the grounding connection.
Class 2 insulation means that the equipment/apparatus is double insulated and is used on some appliances such as electric shavers, hair dryers and portable power tools. Double insulation requires that the devices have and
supplementary insulation, each of which is sufficient to prevent
electric shock. All internal electrically energized components are totally enclosed within insulated packaging which prevents any contact with "live" parts. They can be recognised because their leads have two pins, or on 3 pin plugs the third (
earth) pin is made of plastic rather than metal. In the
EU, double insulated appliances all are marked with a symbol of 2 squares, one inside the other.
Clearance
Distance between two conductors in
gas medium (like
air).
Creepage
Distance between two conductors on a
surface (like a
PCB).
Further Information
Get more info on 'Insulator Electrical'.
|
External Link Exchanges
Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:
<a href="http://insulator__electrical.totallyexplained.com">Insulator (electrical) Totally Explained</a>
Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned. |